Sewage Treatment

GENERAL DESCRIPTION

It is a strong desinfectant and cleaning chemical which eliminates unwanted odors, residues and dirth from the bathrooms, toilets, and washbasins.

USAGE & BENEFITS

  • It is a concentrated product.
  • Easy and quick cleaning.
  • It is a powerful disinfectant and cleaner.

USAGE

Preparing...

GENERAL DESCRIPTION

Toilet water, sink wastes and other waste water in vessels are collected in sewage tank before spilling in ocean, avoiding repeated pollution in environment. GREEN ENZYME is used in treatment of waste water in sewage system.It is a concentrated biologically active powder formulation containing a blend of bacterial strains, specifically developed to deal with sewage wastes.

QUALITY & BENEFITS

  • Fights with unpleasent odors.
  • Avoids block inside pipes.
  • Avoid deposit formations in sewage system.
  • Ensures easy and smooth applications.
  • Does not have negative effects on human and enviromental health.
  • Avoid corrosion

USAGE

Dosing method

Preparing...

Sewage Treatment Plant

Direct dosing to the sewage treatment plant or via the nearest toilet will greatly enhance the biological activity and keep the plant at peak operating efficiency.

A) On ships except passenger vessels Ineffective or septic sewage treatment can be reactivated and maintained in peak operating efficiency by dosing AYT GREEN ENZYME direct in the tank or via the nearest toilet. To reactivate the plant, 1kg GREEN ENZYME should be mixed with 10-15 litres of hand hot (35°C) fresh water, left for 10-15 minutes (stirring periodically) for the bacteria to activate before dosing into the tank daily until the system is operating efficiently. Maintenance dosing of 0.1 - 0.25kg weekly will keep the system operating effectively.
B) On passenger vessels 
The applications is the same as mentioned above, but the dose rates are different. The dose rate depends on the number of people on board the vessel. As a rule of thumb use 50 gram per m 3  of the volume of the sewage tank. Then a weekly dosage of 10 gram per m 3  of the volume of the sewage tank. An example of a cruise vessel with a sewage tank on 100 m 3  and 2500 people and on a two weeks cruise. What is the consumption of AYT GREEN ENZYME
Initial dosage: (50 g/m 3  x 100 m 3  ):1000 = 5kg
Weekly dosage: (10 g/m 3  x 100 m 3  ):1000 x 2 weeks = 2kg
On this cruise, will be used. 7kg of AYT GREEN ENZYME

Tank Cleaning

Holding tanks can be cleaned periodically or prior to entry without the use of dangerous toxic chemicals. Grey and black water holding tanks, sewage tanks, sewage treatment plant should be flooded and pumped empty to clear excess soil before cleaning. Holding tanks must be fitted with an air manifold connected to a low pressure air line of sufficient volume to gently turn the mass of water within the tank. In sewage treatment tanks the normal air supply will suffice. The tank should be filled to 75% capacity with fresh or sea water and the air supply turned on. Approximately 0.5kg of AYT GREEN ENZYME in 5 to 10 litres of fresh hand hot (35°C) water should be mixed and left for 10-15 minutes before dosing into the tank. Dosing can be either direct or via the nearest toilet. The tank should then be filled and left with the air on for at least 48 hours. The dose rate should be approximately 0.5kg per 500 litres tank capacity with a minimum dose of 5kg. Although AYT GREEN ENZYME is formulated for use in cold (15°C minimum) sea water, performance will improve with lukewarm (35°C) fresh water or sea water.

Pipe Cleaning

Maintenance dosing will keep galley and sewage pipes clean and clear of organic residual wastes. A liquid solution should be prepared by mixing of 0.5 kg of AYT GREEN ENZYME in 15 to 20 litres of hand hot (35°C) fresh water. Stir it and, if possible, leave for 15 minutes to reactivate the bacteria. Whilst constantly agitating this solution, 1 litre should be dosed into sinks, scuppers, showers, drains, waste disposal units, etc. each evening until the blockage is cleared. A maintenance dose once or twice a week can then be applied to keep the pipes in clean condition. Harsh toxic cleaners (acids, caustics, disinfectants) should not be used as these will kill off the bacterial action in the pipes. Alternatively, the pipes should be isolated and filled with the solution and left for up to 48 hours before draining. If necessary, further applications should be made until drains run clear.

NOTE: Severly scaled systems should be acid cleaned.

Preparing...

Preparing...

Preparing...